AC Joint
Bilateral AP (Pearson)
IR Size: 14x17 CW or 2@8x10
SID: 72''
Page #'s: 1:209,60

Positioning:
  • Pt. Upright REQUIRED
  • 1st Without Weight, Check for fractures
  • 2nd With 5-8 lb weights each wrist

CR Entrance & Angle:
  • _|_ MSP @ AC Joints
  •

Collimation:
  • 6x17 or 2@6x8

Respiration:
  • Suspend

Best to Determine:
  • AC Joint dislocation, separation & function

Eval Criteria:
  • Both Joints